Plasma Sterilizer Autoclave MPS30
The Plasma Sterilizer Autoclave is the next generation of sterilizer by offering an alternative to high temperature autoclaves that limit which surgical items can be sterilized. Designed to generate plama using Hydrogen Peroxide vapor diffussion technology to sterilize all medical surgery devices, both metallic and non-mettalic at low temperature quickly (<1 hour) and safely
The byproducts produced are passed through a three stage filter and Hydrogen Peroxide catalyst. Since it is converted into a small amount of oxygen and water vapor at discharge, no separate ventilation process is required.
Plasma Sterilizer Autoclave MPS30
The next-generation Plasma Sterilizer Autoclave offers an alternative to high-temperature autoclaves, which limit the types of surgical items that can be sterilized. It is designed to generate plasma using hydrogen peroxide vapor diffusion technology, sterilizing all surgical medical devices—both metallic and non-metallic—at low temperatures quickly (in less than one hour) and safely.
The byproducts produced are passed through a three-stage filter and a hydrogen peroxide catalyst. Since they are converted into only a small amount of oxygen and water vapor at discharge, no separate ventilation process is required.
Product Feature : |
• The sterilizing agent is Hydrogen Peroxide (40–60 wt%). • Automatically opens and closes the door with built-in inter locks that securely lock during the sterilization process. • Features 19 error alarms to prevent incomplete sterilization. • Includes overheat protection,door interlock, and a sterilant injection system to prevent leakage when the sterilizing agent is desorbed. • Fully automatic sterilization control is provided via a micro processor with a 7-inch LCD touch display panel. • Achieves precise air removal using a pre-vacuum method; since the by-products consist of only a small amount of water and oxygen, additional ventilation is not required. • Offers excellent drying of residual moisture through a pre-heat and mechanical ventilation system. • PCD tested for both metallic and non-metallic tools and instruments. |
Product Specifications : |
|
Chamber Size | 9.65″ (W) x 9.65″ (H) x 22.3″ (L) |
Sterilization Temperature | 55°C ± 5°C |
Overall Size | 30″ (W) x 17″ (H) x 28.3″ (L) |
Sterilization Pressure (Diffusion Process) |
0.05 bar – 1.35 bar |
Sterilant | Hydrogen Peroxide (40–60 wt%) |
Air Removal System | Forced ventilation by vacuum pump |
Vacuum Range | 0.04 bar – 1.35 bar |
Vacuum Leak | Average of 1 mmHg/min or below |
Power Consumption | 2400 W |
Control Method | Fully automatic via microprocessor |
Installation Method | Desk type |
Power Requirement | 220V AC, 50/60 Hz |
Display Device | 7-inch full-touch LCD |
Weight | 143 lbs |